Hanwell Instruments
Radiologger  
Call (516) 624 9362 for further details on our products and service
radio transmitters radio transmitters
 

Download this datasheet | Contact Us | E-mail: sales@hanwellusa.com

<<Back

Typical Applications

° Monitoring without wires
° Showcase performance
° Condition monitoring
° Storage monitoring
° Verify BMS systems
° Remote plant control
° Remote heating control
Options & Accessories

° Remote probes
° Fast response air probe
° Surface probe
° Radio booster
° Display version
° Improved calibration
° Mounting/security brackets
° Outdoor version
° Analogue inputs
° User calibration kit


Hanwell instruments Limited (UK)
 
 


Small, discreet and fully portable these incredibly versatile sensors are available in many combinations, temperature/relative humidity and 'lux/UV, CO2, wood moisture, flood detection and many more.

All Hanwell humidity-measuring instruments use Vaisala humidity sensors to guarantee exceptionally high performance and accuracy. Each sensor contains a micro-controller that switches on the sensors at short intervals. The measurement is then carried out, converted to digital form and then transmitted by low power radio using a protocol that ensures complete accuracy of data transfer to the Hanwell Architect. The radio system is fully approved and exceeds all specifications enforced by the relevant national authority and requires no additional license.

The obvious inherent advantages of this option are zero installation costs with no wiring requirement, disruption or damage to what usually are historically sensitive buildings. Simply place the sensor by the object or the local area to be covered and switch on. The sensors are particularly useful for temporary displays or island showcases due to their absolute portability. Each sensor is powered by its own internal battery, which lasts 18 months and is easily replaced. A "battery low" indication is displayed on the Architect, warning of the requirement for battery change prior to complete power loss. A failure in transmission is also flagged by the controller unit.

Hanwell utilise the latest proven technology in their sensors to guarantee high performance and accuracy. Calibration and adjustment is easily effected through the software programme so no physical adjustment is required. Relative Humidity sensors can be calibrated to UKAS standards (United Kingdom Accreditation Service). Annual calibration may be carried out on-site or in Hanwell's own purpose equipped labs.

Specification

Dimensions

110x67x 23mm

Weight
65 grams
Power supply
9 volt PP3 battery, typical life 18 months
Humidity range
0-100% non condensing
Humidity sensor
Capacitive polymer
Humidity accuracy

+/- 2% over full range

Humidity resolution

1%

Temperature sensor

Precision thermistor

Channels
2
Radio frequency
457.6 MHz (up to 32 other channels available)
Power
10 mW
Range
2 miles over open ground
Transmit rate
4 seconds / 5 minutes

Temperature

Range
-25ºC to +80ºC
Accuracy
+/- 0.5 ºC

Humidity

Range
0 to 100% non condensing
Accuracy
+/- 2 % over full range


 
hanwell

Cascade Group Inc| 68 West Main Street | Oyster Bay | New York 11771